Solution of safety protection system for thermal power plant


Background and challenges


Since the reform and opening up, with the rapid development of the national economy, China's power industry has also made rapid growth. Until the end of 2013, China active generating units with a total installed capacity of thermal power accounted for 69%, hydropower accounted for 22%, other forms of power generation accounted for more than 9%, thermal power is still China's main power is the main force in the production of electricity.


In recent years, the international and domestic terrorist activities are active, and the major vicious terrorist incidents occur frequently. Reliable power supply relationship between the stability of society, the thermal power plant as the main power production enterprise, is extremely easy to become the target of terrorist attacks, is the key to prevent the object, the anti-terrorism task is heavy, heavy responsibility. Combined with the domestic in recent years the anti-terrorism situation, to strengthen the safety of power facilities to prevent the construction of standardization, the Ministry of Public Security jointly with the National Energy Bureau formulated the requirements of security risk level and power facilities security (GA1089-2013, hereinafter referred to as "security"), the "security requirements" was released on September 30, 2013 by the Ministry of public security, on November 1, 2013.


Thermal power plant safety prevention system covers the subsystem is numerous, which system comprises a video monitoring system, access control system, parking management system, intrusion alarm system, electronic patrolling system etc.. According to our research on the part of the thermal power plant and Design Institute of communication, found in most power plants only deployed a video monitoring system, intrusion alarm system, access control system (a part of the access control system), and the existing system, there is no effective application of it, such as each of the following should be improved in the system function, resource sharing and business integration on:


1) the existing video monitoring system utilization rate is low, the degree of intelligence is not high, and there are still some key areas of the monitoring blind spot;


Each system in the function to achieve their respective division of labor, in general, the need to install the configuration software and operating software, resulting in the computer room hardware and software redundancy;


2) power plant without security integrated management system, can not achieve the unified monitoring of equipment, increase the system operation and maintenance costs and security risks;


3) there is no unified database, not in the internal information sharing, as well as the unified management and maintenance of system data;


4) most of the system is limited to hardware linkage, increase the complexity of implementation and maintenance;


5) can not configure the overall plan, to achieve a unified platform for business optimization;


6) system administrators need to be familiar with a variety of different styles, different control logic of client management, easy to cause the business is not fine or omission of work;


7) can not achieve remote viewing the entire system running data, most of the system information is not from the management room, is not conducive to the upper management.


In view of the above analysis, the existing thermal power plant integrated security management urgently needs a unified management platform for the integration of the system resources, optimize business management, reduce the cost of investment and operation and maintenance costs.


Construction goal


Security system as the core part of the thermal power plant to prevent terrorism, the importance of stable operation is self-evident. In order to satisfy the safety management of the fire power plant, a set of modern management system adapted to the thermal power plant is set up. System with modern information technology as the support, network interconnection, information resources sharing, application functions, mainly to achieve the following goals:


1) unified integration of subsystems
2) digital and intelligent
3) unified management platform
4) open architecture

5) support HD monitoring


Solution


The overall topology of the system is shown below:



Thermal power plant security system consists of three parts, which are the front end system, the transmission network and the central system.


In the process of system design, in addition to the electric power safety related standards and norms, but also the appropriate technical innovation. FEILIKE thermal power plant security system can achieve the following functions:


1 HD video surveillance: the full access to 1080P and above HD video camera, enhance the quality of video and security level, to meet the requirements of the details of the monitoring (face, vehicle characteristics), support HD video storage;


2) intelligent analysis and recognition: behavior analysis, face recognition, license plate recognition;


3) security system integration: realization of video surveillance, access control management, visitor management, on-line inspections, parking management, intrusion alarm subsystem integration, each subsystem according to plan linkage;


4) three dimensional supervision mode: the realization of the front end, the security control center two vertical regulation, fixed network using B/S, C/S way to access, mobile network through the handheld terminal (mobile phone, tablet, etc.) to carry out supervision;


5) system operation and maintenance management: IT infrastructure management, video quality diagnosis, bandwidth optimization and control, asset management, log management.


Program highlights


1, the technology of system integration
System can be integrated thermal power plant all the security infrastructure protection system, including video surveillance systems, access control systems, intrusion alarm system, patrol system, unified application, realize information data interaction between cross system, alarm linkage response plans and automatically execute, comprehensively improve the overall warning defense capabilities of the power plant.


2, multi intelligent technology integration applications
System using a variety of intelligent analysis technology, real-time video streaming and video playback of video stream frame by frame analysis, automatic filtering useless video images, so that security personnel focus on the value of the video. Intelligent technology applications, equivalent to the power station configuration to "never fatigue" security, and become passive monitoring to active monitoring, in order to power plant security events "beforehand prevention, treatment, post hoc analysis".


3, improve the operation and maintenance management mechanism
System can realize the real-time monitoring and alarming equipment, access control equipment, intercom equipment, patrol equipment, network equipment, storage devices, application server, middleware system, database system, business application system and engine room environment alert, and so, the video equipment, making all kinds of equipment and resources, and through and regulate the flow of operation and maintenance management, data management of electronic, management process standardization, which is the operating environment of the whole network to build unified, perfect, the active process of operation and maintenance, specification of service and centralized management, to enhance the ability of operation and maintenance management.

Search


Advisory
Hotline:0755-29733005
Fax:0755-29733005
Technical:15915491295

Copyright © 2016-2021 Shenzhen HD iDVR Electronics Co., Ltd. All rights reserved ICP No. 09,051,556
Phone: 0755-29733005 Fax: 0755-29733005